Muon reconstruction in release 13.0.10

D. Adams
June 20, 2007


Release 13.0.10 is a reconstruction pre-production release.

For other releases, see the complete list of results.


Issues

1. Hit counts are absent for muid and staco combined.
2. Hole counts are absent for muid and staco combined.
3. Staco combined fit quality now includes constributions from inner and outer tracks. Previously these were absent. Muid still excludes the inner track.
4. Muonboy fit chi-square tail is still large. There is a slight improvement from 12.0.X. Moore is again much better.

Results

Efficiency and fakes are for pT>4 GeV/c, |eta|<2.8 and r0<2 cm.
Cuts are very loose.

All results